 SOGEVAC SV200
| Technical Data | | SOGEVAC SV 200 | SOGEVAC SV 300 | | | Unit | 50 Hz | 60Hz | 50 Hz | 60 Hz | | Nominal speed 1) | m3*h-1 (cfm) | 180 (106) | 220 (129.5) | 280 (164.9) | 340 (200.3) | | Pumping speed 1) | m3*h-1 (cfm) | 170 (100.1) | 200 (117.8) | 240 (141.4) | 290 (170.8) | | Ultimate partial pressure without gas ballast 1) | mbar (Torr) | ?8*10 -2(?6*10 -2) | ?8*10 -2
(?6*10 -2) | ?8*10 -2(?6*10 -2) | ?8*10 -2
(?6*10 -2) | | Ultimate total pressure with gas ballast 1) | mbar (Torr) | ?0.7 (?0.5) | ?0.7 (?0.5) | ?0.7 (?0.5) | ?0.7 (?0.5) | Water vapor tolerance
with standard gas ballast 1)with big gas ballast 2) | mbar (Torr) | 30 (22.5)
50 (37.5) | 40 (30)
50 (37.5) | 30 (22.5)
50 (37.5) | 40 (30)
50 (37.5) | Water vapor capacity
with standard gas ballast | kg*h-1(qt/hr) | 3.4 (3.6) | 5.4 (5.7) | 5.4 (5.7) | 7.4 (7.8) | | Oil capacity, min. | l (qt) | 5.0 (5.3) | 5.0 (5.3) | 8.5 (8.9) | 8.5 (8.9) | | Noise level 3) | dB(A) | 69 | 73 | 70 | 74 | Admissible
ambient temperature | ? (oF) | 12 to 54
(54 to 104) | 12 to 54
(54 to 104) | 12 to 54
(54 to 104) | 12 to 54
(54 to 104) | | Motor power | kW (hp) | 4.0 (5.5) | 5.5 (7.5) | 5.5 (7.5) | 7.5 (10.0) | | Nominal speed | min -1(rpm) | 1450 (1450) | 1750 (1750) | 1450 (1450) | 1750 (1750) | | Type of protection | IP | 55 | TEFC/55 5) | 55 | TEFC/55 5) | | Weight (with oil filling) | kg (lbs) | 140 (308.7) | 155 (341.8) | 180 (396.9) | 195 (430) | | Dimensions (W*H*D) | mm (in.) | 940*535*415
(37*21.06*17.71) | 1080*535*415
(42.51*21.06*17.71) | | Connections4)Intake, thread Exhaust, thread | G (BSP)
G (BSP) | 2”
2” | 2”
2” | 2”
2” | 2”
2” |
1) To DIN 28 400 and following numbers
2) Ordering Information see Section “Accessories”
3) Operated at the ultimate pressure without or with gas ballast, free-field measurement at a distance of 1 m
4) European and Japanese pumps have BSP, North and South American versions have NPT
5) CEI motor (Europe) 50/60 Hz has IP 55, NEMA motor (North and South America) has TEFC
|